Application Tag Commands
136 Command Set
TrExt as Per Gen2 (1 byte: Current fixed to 0x01, M5e and M5e-C only support
extended Pilot Tone)
It is invoked with the following command, it does not support tag singulation:
The response to the EAS Alarm command contains 8 bytes of EAS Alarm Data, only if
Status=0x0000. The format of the response is:
Note
EASAlarm cannot be embedded in Read Tag Multiple.
FF 09 2D 03 E8 02 4o 00 04 01 02 01 ?? ??
SOH Length OpCode Timeout (ms) Chip
Type
Option Sub
Cmd
DR M TrExt CRC
FF 0A 2D 00 00 02 44 00 04 [8 bytes] ?? ??
SOH Length OpCode Status Chip
Type
Option Sub
Cmd
[EAS Alarm
Data]
CRC