Application Tag Commands
88 Command Set
updating the Option field to set the appropriate flag for the tag singulation based on EPC
value
The response contains the requested metadata and the tag EPC matching the requested
tag EPC:
Error Status Codes
FAULT_MSG_WRONG_NUMBER_OF_DATA – 100h
FAULT_MSG_INVALID_PARAMETER_VALUE - 105h
FAULT_NO_PROTOCOL_DEFINED – 401h
FAULT_AFE_NOT_ON – 405h
FAULT_NO_TAGS_FOUND – 400h
FAULT_ANTENNA_NOT_CONNECTED – 503h
FAULT_TEMPERATURE_EXCEED_LIMITS – 504h
FAULT_HIGH_RETURN_LOSS – 505h
FF 12 21 01 E8 11 00 14
SOH Length OpCode Timeout Options Metadata Flags
60 11 11 22 22 33 33 44 44 55 55 66 66
9F
C
E
Select
Data
Length
Select Data (EPC) CRC
FF 16 21 00 00 11 00 14
SO
H
Length OpCod
e
Status Options Metadata
Flags
22 0F C8 CD B7 11 11 22 22 33 33 44 44 55 55 66 66 18 35
Ant
ID
Timestamp Tag EPC Tag CRC
FE 7D
CRC