Thingmagic M5e-Compact Manual do Utilizador Página 175

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 252
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 174
Get Application Commands
Command Set 175
Get Write TX Power (64h)
For deprecated version of this command see Appendix D: Get Write TX Power (64h)
The Get Write TX Power command returns the current TX power and, optionally, the
minimum and maximum power levels supported by the module for reading tags, in centi-
dBm.
The option field allows you to specify what data you want returned:
The following example gets the full set of power data:
The example response contains the option specified followed by 2 byte fields for each
power value:
current = 0x0BB8 = 3000 centi-dBm = 30.00 dBm
max = 0x0BB8 = 3000 centi-dBm = 30.00 dBm
min. = 0x01F4 = 500centi-dBm = 5.00 dBm
Get Frequency Hop Table (65h)
The Get Frequency Hop Table command gets the current frequency hop table and,
optionally, the frequency hop time, used.
Get Frequencies
The following command gets the list of frequencies current used in the hop table.
Option Data returned
0x00 Returns only the current TX power.
0x01 Returns the current TX power and the maximum
and minimum power levels for this module.
FF 01 64 01 B8 BC
SOH Length OpCode Option CRC
FF 07 64 00 00 01 0B B8 0B B8 01 F4 FF BC
SOH Length OpCode Status Option Default centi-dBm Max centi-dBm Min centi-dBm CRC
Vista de página 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 251 252

Comentários a estes Manuais

Sem comentários