Application Tag Commands
140 Command Set
NXP G2i* Command Fields
An example ChangeConfig single tag command is:.
The response to the ChangeConfig command contains the new value of the tag’s
ConfigWord after the Config Data toggle bits have been appled. The format of the
Field Value Notes
Length [1 byte]
OpCode 0x2D
Timeout [2 bytes] Ignored when used as an embedded command
for
Tag Inventory With Embedded Operations
Chip Type 0x07 0x07 - NXP G2i*
Tag Singulation Fields
| Select Option
[1 byte] • bit 6 (x1xx xxxx | 0x40) must be set,
indicating a 2-byte sub command follows this
byte, and before the remaining
Tag
Singulation Fields
Sub Command [2 bytes]
• 0x0007 -
ChangeConfig
Access Password [4 bytes] Must be non-zero for ChangeConfig. If zero the
ConfigWord will not be changed.
Tag Singulation Fields
| Select [Address,
Data Length, Data]
[n bytes]
The remaining fields from the Tag Singulation
Fields
Note: Optional depending on the value of
Select Option.
RFU 0x00 RFU
Config Data [2 bytes]
Toggle memory bits as defined by
ConfigWord
to Command Bit Address Map
• ‘1’ - Toggle memory bit
• ‘0’ - Leave memory alone
FF 10 2D 03 E8 07 44 00 07 11 22 33 44 00 00 00 78 08 34
SOH Length OpCode Timeout (ms) Chip
Type
Option Sub
Cmd
Access Password Select Data Address Select
Length
Selct
Data
00 00 00 ?? ??
RFU Config Data CRC
Comentários a estes Manuais