Set Application Commands
Command Set 159
Set Regulatory Hop Time Command Fields (Option = 0x01)
Note
Option=0x00 is reserved and not the same as when no option is specified.
Set User GPIO Outputs (96h)
There are two GPIO outputs available for use. The Set User GPIO Outputs command
has been “overloaded” to create a mechanism to return the current state of both GPIO
pins. To set either GPIO Output pin, send the following command. Note that the data
length is 2 bytes:
Field Value Description
Length 0x05 Number of bytes after OpCode
OpCode 0x95 Set Frequency Hop Table
Option 0x01 Indicates the Regulatory Hop Time will be passed.
Regulatory Hop
Time
[4 bytes] The time between frequency hops, in milli-seconds, to be
used for the defined hop table.
Note: The max hop time is restricted by regulatory limits based
on the region set via
Set Current Region (97h).
FF 02 96 01 01 28 E0
SOH Length OpCode GPIO # Output Value CRC